Our 925 sterling silver is tested by SGS. Our stainless steel is tested by CTT, a CNAS-accredited laboratory. Every report is published in full, with the laboratory's own QR code to verify it.

4
Reports
2
Laboratories
9/9
Tests passed

Sterling silver & moissanite

925 Sterling Silver

Tested by SGS-CSTC Standards Technical Services

  • Silver purity 925 silver means at least 92.5% pure silver 93.2% pure silver925 standard: at least 92.5%
  • Nickel release (EU) How much nickel can reach the skin; the EU limits it for jewelry Not detectedLimit ≤ 0.5 µg/cm²/week
  • Lead A heavy metal the EU restricts in jewelry Not detectedLimit ≤ 500 mg/kg
  • Cadmium A heavy metal the EU restricts in jewelry Not detectedLimit ≤ 0.01%
2 reports · updated 2026-11-11 See results and reports →

Stainless steel

Stainless Steel

Tested by CTT · CNAS L3068 · ILAC-MRA

  • 316 stainless steel 316 contains molybdenum (Mo); ours 2.29% Confirmed 316earring sample
  • 316L stainless steel Low-carbon 316: carbon at most 0.03% (ours 0.025%) Confirmed 316Lpendant sample
  • Nickel release (EU) How much nickel can reach the skin; the EU limits it for jewelry Not detectedLimit ≤ 0.88 µg/cm²/week
  • Lead A heavy metal the EU restricts in jewelry 22 mg/kgLimit ≤ 500 mg/kg
  • Cadmium A heavy metal the EU restricts in jewelry Not detectedLimit ≤ 100 mg/kg
2 reports · updated 2026-11-06 See results and reports →

SGS · Sterling silver & moissanite

925 sterling silver: silver content, nickel, lead and cadmium passed

Samples: 925 sterling silver moissanite rings from our catalogue

TestStandardResultLimitReportPass
Silver purity ISO 11427:2024932‰ (93.2% pure silver)≥ 925‰SZHL261105739601TC · p.2✓ Pass
Nickel release (EU) after simulated wear, 3 trialsREACH Annex XVII #27 · EN 12472:2020 + EN 1811:2023Not detected (< 0.10 µg/cm²/week)≤ 0.5 µg/cm²/weekGZHL261006010301JW · p.2✓ Pass
Lead ring and stone tested separatelyREACH Annex XVII #63Not detected (< 20 mg/kg)≤ 500 mg/kgGZHL261006010301JW · p.3✓ Pass
Cadmium REACH Annex XVII #23Not detected (< 0.0005%)≤ 0.01%GZHL261006010301JW · p.2✓ Pass

Original reports

Report No. SZHL261105739601TC

SZHL261105739601TC

Silver purity

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
Issued 2026-11-10 · 3 pages

SGS verification QR code for this test report Verify on SGS
Report No. GZHL261006010301JW

GZHL261006010301JW

Nickel release (EU), Lead, Cadmium

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
Issued 2026-11-11 · 4 pages

SGS verification QR code for this test report Verify on SGS

As stated by the laboratory, results apply to the samples as received. Signed PDFs are available to customers with a paid order.

CTT · Stainless steel

Stainless steel: 316 and 316L confirmed, nickel, lead and cadmium passed

Samples: stainless steel jewelry from our catalogue

TestStandardResultLimitReportPass
316 stainless steel earring sampleASTM A959-19Cr 17.83% · Ni 11.62% · Mo 2.29% · C 0.064%within rangeCTT26090107358EN · p.3✓ Pass
316L stainless steel pendant sampleASTM A959-19Cr 16.26% · Ni 10.59% · Mo 2.07% · C 0.025%within rangeCTT26110100367EN · p.3✓ Pass
Nickel release (EU) REACH Annex XVII #27 · EN 1811:2023Not detected (< 0.05 µg/cm²/week)≤ 0.88 µg/cm²/weekCTT26090107358EN · p.4✓ Pass
Lead REACH Annex XVII #6322 mg/kg≤ 500 mg/kgCTT26090107358EN · p.4✓ Pass
Cadmium REACH Annex XVII #23Not detected (< 2 mg/kg)≤ 100 mg/kgCTT26090107358EN · p.5✓ Pass

Original reports

Report No. CTT26090107358EN

CTT26090107358EN

316 stainless steel, Nickel release (EU), Lead, Cadmium

Guangdong Consumer Testing Technology Co., Ltd. (CTT) · CNAS L3068 · ILAC-MRA
Issued 2026-10-09 · 6 pages

CTT verification QR code for this test report Verify on CTT
Report No. CTT26110100367EN

CTT26110100367EN

316L stainless steel

Guangdong Consumer Testing Technology Co., Ltd. (CTT) · CNAS L3068 · ILAC-MRA
Issued 2026-11-06 · 4 pages

CTT verification QR code for this test report Verify on CTT

As stated by the laboratory, results apply to the samples as received. Signed PDFs are available to customers with a paid order.

The signed PDF report is available to customers with a paid order: sign in with the account you ordered with to download it. Every page of the report can be viewed above.

Buyer questions

What the reports answer.

925 sterling silver · SGS

Is your 925 sterling silver tested?

Yes. SGS measured the silver content of a 925 sterling silver moissanite ring from our catalogue in report SZHL261105739601TC (ISO 11427:2024, potentiometric titration): 932‰ silver, above the 925‰ minimum for sterling silver. Every page of the report is on this page, and its QR code opens the report on SGS's own system. The result applies to the sample tested.

Does your 925 sterling silver meet EU limits for nickel, lead and cadmium?

Yes, on the sample tested. In report GZHL261006010301JW, SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch tested a 925 sterling silver moissanite ring from our catalogue against EU REACH: nickel release after simulated wear (EN 12472 + EN 1811), lead in the ring and the stone, and cadmium in the ring. None of the three was detected, so all passed. Every page of the report is on this page, and its QR code opens it on SGS's own system.

Stainless steel · CTT

Do you have third-party test reports for your stainless steel jewelry?

Yes. A sample of our stainless steel jewelry was tested by Guangdong Consumer Testing Technology Co., Ltd. (CTT), a CNAS-accredited laboratory (ILAC-MRA), in report CTT26090107358EN: composition to ASTM A959, EU nickel release (EN 1811), lead and cadmium under EU REACH. Every test passed, and every page of the report is published on this page. The results apply to the sample tested.

Is your jewelry nickel-free?

Stainless steel jewelry usually contains nickel (the tested sample: 11.62%). What EU law controls for skin contact is nickel release, measured with EN 1811. In our report, nickel release was below the detection limit (< 0.05 µg/cm²/week), far under the EU limit of 0.5 µg/cm²/week.

Does it meet EU REACH limits for lead and cadmium?

Yes. Lead measured 22 mg/kg against the REACH limit of 500 mg/kg, and cadmium was not detected (< 2 mg/kg) against a limit of 100 mg/kg.

All reports

How can I check that the report is genuine?

Scan the QR code on this page (it is the code printed on the report itself). It opens report CTT26090107358EN on the laboratory's official system, which shows the report number, issue date and its status: Valid. You can also contact Guangdong Consumer Testing Technology Co., Ltd. (CTT) with the report number.

Can I get the signed PDF for my customers or customs?

Yes, for customers with an order. Sign in with the account you ordered with and use the download button on this page. Anyone can view every page of the report here.

Ask any supplier for the paperwork before you order. We publish ours.

Questions about a specific product, material or test? Send us the product link and we will tell you exactly what the paperwork covers.